FieldFox Competitive Information

What are you looking for?

FieldFox RF/Microwave Analyzers
 
Competitive Information - Anritsu
 
Keysight
FieldFox B-Series
N991xB, N993xB,
N995xB, N996xB
Keysight
FieldFox A-Series
N991xA, N993xA,
N995xA, N996xA
Anritsu
Field Master Pro MS2090A Spectrum Master MS2720T VNA Master MS2036C Site Master S820E, S3xxE
Cable Antenna Test (CAT) ■ ■     ■ ■
Vector Network Analyzer (VNA) ■ ■     ■
■ 
Spectrum Analyzer (SA) ■ ■ ■ ■ ■  
Real-time Spectrum Analyzer (RTSA) ■ ■ ■      
Real-time bandwidth 120 MHz 10 MHz 110 MHz      
Maximum frequency range 30 [300] kHz to 54 GHz 5 [300] kHz to 50 GHz 9 kHz to 54 GHz 20 GHz 5 kHz to 6 GHz (VNA), 9 kHz to 9 GHz (SA) 1 MHz to 40 GHz
VNA dynamic range 117 dB 100 dB     100 dB 115 dB
SA amplitude accuracy* ± 0.2 dB ± 0.5 dB ± 0.5 dB ± 0.5 dB ± 0.5 dB  
Displayed Average Noise Level (DANL) –163 dBm @ 2 GHz [–151] dBm @ 40 GHz –159 dBm @ 2 GHz –144 dBm @ 40 GHz –164 dBm @ 2 GHz –154 dBm @ 40 GHz –163 dBm @ 2 GHz –164 dBm @ 2 GHz  
Third-Order Intercept (TOI) +13.5 [+16] dBm +15 dBm +20 dBm +14 dBm +14 dBm  
Phase noise, CF = 1 GHz, 10 kHz offset –117 [–113] dBc/Hz –111 dBc/Hz –106 dBc/Hz –112 dBc/Hz –106 dBc/Hz  
Sweep speed (CAT) 409 [457] μs/data point 650 μs/data point     350 μs/data point 650 μs/data point
Operating temperature –10 to +55 °C –10 to +55 °C –10 to +55 °C –10 to +55 °C –10 to +55 °C –10 to +55 °C
Weight 3.34 kg (7.35 lb) 3.34 kg (7.35 lb) 5.4 kg (11.15 lb) 4.4 kg (9.8 lb) 4.8 kg (10.5 lb) 3.0 kg (6.6 lb)
Battery time 4 hours 4 hours 2 hours 3 hours 3 hours 6 hours
 
Competitive Information - Rhode & Schwartz
 
Keysight FieldFox B-Series
N991xB, N993xB, N995xB, N996xB
Keysight
FieldFox C-Series
N991xC, N993xC
Rhode & Schwarz
FSH Handheld Spectrum Analyzer
FSH4, FSH8, FSH13, FSH20
ZVH Cable and Antenna Analyzer ZVH4, ZVH8 Portable Receiver PR200
Cable Antenna Test (CAT) ■ ■ ■ ■  
Vector Network Analyzer (VNA) ■ ■ ■ ■  
Spectrum Analyzer (SA) ■ ■ ■ ■ ■
Real-time Spectrum Analyzer (RTSA) ■ ■     ■
Real-time bandwidth 120 MHz Up to 120 MHz     40 MHz
Maximum frequency range 30 [300] kHz to 54 GHz 3 kHz up to 10 GHz 9 kHz to 20 GHz (SA), 100 kHz to 8 GHz (VNA) 100 kHz to 8 8 kHz to 8 GHz
VNA dynamic range 117 dB 118 dB   100 dB  
SA amplitude accuracy* ± 0.2 dB ± 0.15 dB ± 1.3 dB ± 1.3 dB  
Displayed Average Noise Level (DANL) –163 dBm @ 2 GHz[–151] dBm @ 40 GHz
–165 dBm @ 2 GHz
–163 dBm @ 2 GHz –163 dBm @ 2 GHz  
Third-Order Intercept (TOI) +13.5 [+16] dBm +10.5 dBm +15 dBm +10 dBm (nom.)  
Phase noise, CF = 1 GHz, 10 kHz offset –117 [–113] dBc/Hz –112 dBc/Hz –105 dBc/Hz (30 kHz offset) –105 dBc/Hz (30 kHz offset)  
Sweep speed (CAT) 409 [457] μs/data point 461 μs/data point   Not specified  
Operating temperature –10 to +55 °C –10 to +55 °C –10 to +55 °C –10 to +55 °C –10 to +55 °C
Weight 3.34 kg (7.35 lb) 3.34 kg (7.35 lb) < 3 kg (6.6 lb) < 3 kg (6.6 lb) 3.5 kg (7.7 lb)
Battery Time 4 hours 4 hours 4.5 hours 4.5 hours 4 hours
Note: The performance values within bracket [ ] are specifically for N995x and/or N996x.
*No warm-up is required for FieldFox; however, a 60-minute warm-up is required for Anritsu products. Both are operational at full temperature (-10 to 55°C). R&S only offers specifications at room temperature.